Difference between revisions of "BMC Atrium - Common Data Model"
PeterHarding (talk | contribs) |
PeterHarding (talk | contribs) |
||
(9 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
=BMC Atrium CMDB 2.1.00 Common Data Model= | =BMC Atrium CMDB 2.1.00 Common Data Model= | ||
See [http://www.performiq.com.au/kb/images/CMDB2.1.00_CDM_Diagram_Visio.vsd here] for Visio | [[Image:CMDB2.1.00_CDM_Diagram.png]] | ||
See [http://www.performiq.com.au/kb/images/CMDB2.1.00_CDM_Diagram_Visio.vsd here] for Visio version of schema. | |||
The following is a summary of the defined elements... | |||
==Class Hierarchies== | ==Class Hierarchies== | ||
Line 145: | Line 149: | ||
AddressType, explorationDate, PrefixLength, SubnetMask, SubnetNumber | AddressType, explorationDate, PrefixLength, SubnetMask, SubnetNumber | ||
==BMC_IPXConnectivityNetwork=== | ===BMC_IPXConnectivityNetwork=== | ||
NetworkNumber | NetworkNumber | ||
Line 160: | Line 164: | ||
count, resolutionDate, WANType | count, resolutionDate, WANType | ||
==Component Hierarchy== | ==Component Hierarchy== | ||
Line 183: | Line 186: | ||
ActiveMaximumTransmissionUnit, AutoSense, FullDuplex, LinkTechnology, MaxSpeed, NetworkAddresses, PermanentAddress, PhysicalDescription, PortType, Speed, SupportedMaximumTransmissionUnit | ActiveMaximumTransmissionUnit, AutoSense, FullDuplex, LinkTechnology, MaxSpeed, NetworkAddresses, PermanentAddress, PhysicalDescription, PortType, Speed, SupportedMaximumTransmissionUnit | ||
===BMC_PointingDevice=== | |||
DeviceInterface, NumberOfButtons, PointingType | |||
===BMC_Processor=== | |||
Level, MaxClockSpeed, OtherProcessorFamilyDescription, ProcessorArchitecture, ProcessorFamily, ProcessorStatus, ProcessorType, UpgradeMethod | |||
===BMC_UPS=== | |||
BatteryInstalled, InputVoltage, IsSwitchingSupply, TimeOnBackup, TotalOutputPower, TypeOfRangeSwitching, UPSPort | |||
===BMC_HardwarePackage=== | |||
No attributes | |||
====BMC_Card==== | |||
CardType | |||
====BMC_Chassis==== | |||
ChassisType, NumberOfPowerCords, RackMountable | |||
====BMC_Rack==== | |||
Height, TypeOfRack | |||
===BMC_Media=== | |||
Capabilities, CompressionMethod, DefaultBlockSize, DriveInterfaceType, DriveSCSITargetID, DriveSize, MaxBlockSize, MaxMediaSize, MediaType, MinBlockSize, NumberOfMediaSupported | |||
====BMC_CDROMDrive==== | |||
MaxComponentLength, TransferRate | |||
====BMC_DiskDrive==== | |||
InterfaceType (deprecated), Partitions, SCSIBus, SCSILogicalUnit, SCSIPort, SCSITargetID (deprecated), SectorsPerTrack, Size (deprecated), TotalCylinders, TotalHeads, TotalSectors, TotalTracks, TracksPerCylinder | |||
====BMC_FloppyDrive==== | |||
No attributes | |||
====BMC_TapeDrive==== | |||
No attributes | |||
==Logical System Component Hierarchy== | |||
===BMC_LogicalSystemComponent=== | |||
No attributes | |||
===BMC_DiskPartition=== | |||
BlockSize, Bootable, NumberOfBlocks, PrimaryPartition | |||
===BMC_Share=== | |||
AccessMask, MaximumAllowed, Path | |||
===BMC_SystemResource=== | |||
Properties | |||
===BMC_FileSystem=== | |||
No attributes | |||
====BMC_DataBaseStorage==== | |||
isSystemArea, LastBackupTime | |||
====BMC_LocalFileSystem==== | |||
No attributes | |||
===BMC_RemoteFileSystem=== | |||
No attributes | |||
===BMC_Software=== | |||
BuildNumber, BuildType, ConfigurationBasicNumber, ContractID, InstallLocation, LicensesAvailable, LicenseType, PatchNumber, ServicePack | |||
====BMC_Patch==== | |||
ServicePackInEffect, SeverityRating | |||
====BMC_Product==== | |||
No attributes | |||
=====BMC_Package===== | |||
No attributes | |||
====BMC_SystemSoftware==== | |||
No attributes | |||
=====BMC_BIOSElement===== | |||
BiosCharacteristics, PrimaryBIOS, PrimaryOS | |||
=====BMC_OperatingSystem===== | |||
CountryCode, MaxNumberOfProcesses, MaxProcessMemorySize, Organization, OSLanguage, OSProductSuite, OSType, PAEEnabled, ProductType, SuiteMask, SystemDirectory | |||
=====BMC_VirtualSystemEnabler===== | |||
EnablerType | |||
======BMC_VMWare====== | |||
VMImageName | |||
[[Category:ITIL]] | |||
[[Category:CMDB]] |
Latest revision as of 17:11, 1 March 2008
BMC Atrium CMDB 2.1.00 Common Data Model
See here for Visio version of schema.
The following is a summary of the defined elements...
Class Hierarchies
Subclasses inherit attributes and relationships of all superclasses
- Regular class
- Categorization class
- Abstract class
- Superclass
- Subclass
- Source class (Class 1)
- Destination class (Class 2)
Relationships
- Component relationship
- Dependency relationship
- Element Location relationship
- Member Of relationship
Connections
- Component
- Member of Collection
- Dependency
- Base Relationship
- Base Element
Hierarchy
BMC_BaseElelemt
AccountID, AssignedTo, AttributeDataSourceList, Availability, Category, ClassId, CMDBRowLevelSecurity, CMDBWriteSecurity, CompareActionCode, Confidentiality, CreateDate, DatasetId, deleted, DeleteInstanceTrigger, Description, FailedAutomaticIdentification, History, InstanceId, Integrity, Item, LastModifiedBy, LastREJobrunId, LastScanDate, ManufacturerName, MarkAsDeleted, Model, ModifiedDate, Name, NameFormat, Notes, OpIdWeakReference, OwnerContact, OwnerName, Priority, ReconciliationIdentity, ReferenceInstance, RelLeadClassId, RelLeadInstanceId, RequestId, SerialNumber, ShortDescription, status, Submitter, Supported, TmpOpOriginationForm, TokenFormat, TokenId, Type, VersionNumber
BMC_Person
Email, Fax, FirstName, LastName, MiddleName, MobilePhone, OfficePhone, PagerEmail, PagerParams1, PagerParams2, PagerPhoneNumber, PagerPINNumber, PagerProvider, PagerSoftware, PagerType, PersonAdditionalDetails, PersonDepartment, PersonRegion, SecondaryEmail, Title, WebPage
BMC_LogicalEntity
No attributes
BMC_Collection
No attributes
BMC_AccessPoint
SystemClassId SystemName
BMC_SystemComponent
SystemClassId SystemName
BMC_SystemService
SystemClassId SystemName
BMC_Equipment
No attributes
BMC_System
No attributes
BMC_Document
Author DocumentAttachment DocumentDate DocumentSize DocumentStatus DocumentType FileName Keywords Locale
BMC_Settings
No attributes
Access Point Lower Layers
BMC_ProtocolEndPoint
Address, ProtocolType
BMC_CommunicationEndpoint
PortNumber
BMC_IPEndpoint
AddressType, DNSHostName, PrefixLength, SubnetMask
BMC_LANEndpoint
AliasAddresses, GroupAddresses, LANID, MACAddress
Collection Lower Layers
BMC_ConcreteCollection
No attributes
BMC_Organization
BusinessCategory, Email, URI
BMC_Role
CommonName
BMC_UserCommunity
Count, SPOC
BMC_ConnectivityCollection
ConnectivityCollectionType, ConnectivityStatus
BMC_ConnectivitySegment
ConnectivityType, count, fixed, NetworkID, OtherTypeDescription
BMC_IPConnectivitySubnet
AddressType, explorationDate, PrefixLength, SubnetMask, SubnetNumber
BMC_IPXConnectivityNetwork
NetworkNumber
BMC_LNsCollection
No attributes
BMC_LAN
resolutionDate
BMC_WAN
count, resolutionDate, WANType
Component Hierarchy
BMC_HardwareSystemComponent
PNPDeviceID, PowerManagementCapabilities, PowerManagementSupported, SystemAvailability
BMC_Keyboard
Layout
BMC_Memory
Capacity, FormFactor, HotSwappable, MemoryType, Removable, Replaceable, Speed
BMC_Monitor
Bandwidth, DisplayType, PixelsPerXLogicalInch, PixelsPerYLogicalInch, ScreenHeight, ScreenWidth
BMC_NetworkPort
ActiveMaximumTransmissionUnit, AutoSense, FullDuplex, LinkTechnology, MaxSpeed, NetworkAddresses, PermanentAddress, PhysicalDescription, PortType, Speed, SupportedMaximumTransmissionUnit
BMC_PointingDevice
DeviceInterface, NumberOfButtons, PointingType
BMC_Processor
Level, MaxClockSpeed, OtherProcessorFamilyDescription, ProcessorArchitecture, ProcessorFamily, ProcessorStatus, ProcessorType, UpgradeMethod
BMC_UPS
BatteryInstalled, InputVoltage, IsSwitchingSupply, TimeOnBackup, TotalOutputPower, TypeOfRangeSwitching, UPSPort
BMC_HardwarePackage
No attributes
BMC_Card
CardType
BMC_Chassis
ChassisType, NumberOfPowerCords, RackMountable
BMC_Rack
Height, TypeOfRack
BMC_Media
Capabilities, CompressionMethod, DefaultBlockSize, DriveInterfaceType, DriveSCSITargetID, DriveSize, MaxBlockSize, MaxMediaSize, MediaType, MinBlockSize, NumberOfMediaSupported
BMC_CDROMDrive
MaxComponentLength, TransferRate
BMC_DiskDrive
InterfaceType (deprecated), Partitions, SCSIBus, SCSILogicalUnit, SCSIPort, SCSITargetID (deprecated), SectorsPerTrack, Size (deprecated), TotalCylinders, TotalHeads, TotalSectors, TotalTracks, TracksPerCylinder
BMC_FloppyDrive
No attributes
BMC_TapeDrive
No attributes
Logical System Component Hierarchy
BMC_LogicalSystemComponent
No attributes
BMC_DiskPartition
BlockSize, Bootable, NumberOfBlocks, PrimaryPartition
AccessMask, MaximumAllowed, Path
BMC_SystemResource
Properties
BMC_FileSystem
No attributes
BMC_DataBaseStorage
isSystemArea, LastBackupTime
BMC_LocalFileSystem
No attributes
BMC_RemoteFileSystem
No attributes
BMC_Software
BuildNumber, BuildType, ConfigurationBasicNumber, ContractID, InstallLocation, LicensesAvailable, LicenseType, PatchNumber, ServicePack
BMC_Patch
ServicePackInEffect, SeverityRating
BMC_Product
No attributes
BMC_Package
No attributes
BMC_SystemSoftware
No attributes
BMC_BIOSElement
BiosCharacteristics, PrimaryBIOS, PrimaryOS
BMC_OperatingSystem
CountryCode, MaxNumberOfProcesses, MaxProcessMemorySize, Organization, OSLanguage, OSProductSuite, OSType, PAEEnabled, ProductType, SuiteMask, SystemDirectory
BMC_VirtualSystemEnabler
EnablerType
BMC_VMWare
VMImageName